{"product_id":"microlife-non-contact-thermometer-nc200-1-stuks","title":"Microlife Non-contact thermometer NC200 1 Piece","description":"\u003cb\u003eMicrolife Non-contact thermometer NC200\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eThis Microlife thermometer is a high-quality product that incorporates the latest technology and has been tested according to international standards. With its unique technology, this thermometer can provide a stable reading free from heat interference with each measurement. Each time the thermometer is turned on, the device automatically performs a self-test to ensure the accuracy of the measurements.\r\u003cbr\u003e\r\u003cbr\u003eThis thermometer has been clinically tested, found to be safe and accurate when used in accordance\r\u003cbr\u003ewith its user manual.\r\u003cbr\u003e\r\u003cbr\u003eTechnical specifications\r\u003cbr\u003eType: Custom mode non-contact thermometer NC 200\r\u003cbr\u003eMode type: Adjustable mode\r\u003cbr\u003eMeasurement site: Forehead\r\u003cbr\u003eReference to body site: Under the tongue\r\u003cbr\u003eMeasurement range: Body mode: 34.0 - 43.0 °C \/ 93.2 - 109.4 °F\r\u003cbr\u003eObject mode: 0.1 - 99.9 °C \/ 32.2 - 211.8 °F\r\u003cbr\u003eResolution: 0.1 °C \/ °F\r\u003cbr\u003eStorage conditions: -25 - +55 °C \/ -13 - +131 °F\r\u003cbr\u003e15 - 95 % maximum relative humidity\r\u003cbr\u003eAutomatic shut-off: Approximately 1 minute after the last measurement.\r\u003cbr\u003eBattery: 2 x 1.5V alkaline batteries; type AAA\r\u003cbr\u003eBattery life: approximately 2000 measurements (with new batteries)\r\u003cbr\u003eDimensions: 156.7 x 43 x 47 mm\r\u003cbr\u003eWeight: 91.5 g (with battery), 68.5 g (without battery)\r\u003cbr\u003eIP Class: IP22\r\u003cbr\u003eReference to\r\u003cbr\u003estandards: ISO 80601-2-56; IEC 60601-1; IEC 60601-1-2 (EMC)\r\u003cbr\u003eExpected lifespan: 5 years or 12000 measurements\u003cbr\u003eMeasurement in just a few seconds\r\u003cbr\u003eThe innovative infrared technology makes it possible to complete a measurement without contact with the body. This guarantees\r\u003cbr\u003ea safe and hygienic measurement within seconds.\r\u003cbr\u003eAutomatic measurement with distance control\r\u003cbr\u003eThis device can automatically take a measurement when the\r\u003cbr\u003edesired distance within 5 cm is reached.\r\u003cbr\u003eMultiple applications (large measuring range)\r\u003cbr\u003eThis thermometer has a large measuring range of 0.1 - 99.9 °C \/\r\u003cbr\u003e32.2 - 211.8 °F; the thermometer can be used to\r\u003cbr\u003eto measure body temperature, but can also be used\r\u003cbr\u003efor measuring the surface temperature of:\r\u003cbr\u003eMilk in a baby's bottle\r\u003cbr\u003eThe water in a baby's bath\r\u003cbr\u003eThe ambient temperature\r\u003cbr\u003e\r\u003cbr\u003eAccurate and reliable\r\u003cbr\u003eThe unique probe tip with built-in advanced infrared sensor ensures that each measurement is accurate and reliable.\r\u003cbr\u003e\r\u003cbr\u003eUser-friendly and simple to use\r\u003cbr\u003eThe ergonomic design makes the thermometer handy and easy to use.\r\u003cbr\u003eThis thermometer can even be used on a sleeping child, who can continue to sleep peacefully.\r\u003cbr\u003eThis thermometer is quick and therefore pleasant to use for children\r\u003cbr\u003eRead multiple measurements\r\u003cbr\u003eUsers can consult the last 30 measurements by activating the memory mode. This allows you to easily\r\u003cbr\u003eTracking temperature variations.\r\u003cbr\u003e\r\u003cbr\u003eSafe and hygienic\r\u003cbr\u003e- No direct contact with the skin.\r\u003cbr\u003e- No risk of broken glass or swallowing mercury.\r\u003cbr\u003e- Completely safe for children.\r\u003cbr\u003e\r\u003cbr\u003eFever alarm\r\u003cbr\u003e- 10 short beeps and a red illuminated LCD alert you that a temperature above 37.5 °C has been measured.\r\u003cbr\u003e- Tracking system for self-measurement\r\u003cbr\u003e- A green light on the back side shows the user if the correct distance has been reached and a measurement is automatically taken.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWhat this product is used for\u003c\/b\u003e\u003cbr\u003eThe Microlife thermometer is intended to measure and monitor human body temperature.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003eTaking temperature with this thermometer\r\u003cbr\u003eThe thermometer measures the infrared radiation emitted by the forehead or other objects. This energy is captured by the lens and converted into a temperature value.\r\u003cbr\u003e\r\u003cbr\u003eControl screen and symbols\r\u003cbr\u003eAll symbols appear 9: Press the START\/IO button to activate the thermometer, all symbols will appear on the screen for 1 second.\r\u003cbr\u003eReady for measurement AT: When the thermometer is ready for the measurement, the symbol «°C» or «°F» will continue to blink, while the body or object symbol is continuously displayed.\r\u003cbr\u003eCountdown for measurement BR: A 3-second countdown is shown on the display (3, 2, 1) before each measurement.\r\u003cbr\u003eMeasurement completed AK: The measurement will be displayed on display 4 while both the ear or forehead symbol and the symbol for «°C» or «°F» are continuously displayed.\r\u003cbr\u003eAs soon as the symbol «°C» or «°F» starts blinking again, the device is ready for the next measurement.\r\u003cbr\u003eLow battery level AN: When the thermometer is turned on, the icon continues to blink to remind you that the batteries need to be replaced.\r\u003cbr\u003e\r\u003cbr\u003eSetting date, time, and beeper functions\r\u003cbr\u003eDate and time setting\r\u003cbr\u003eAfter the batteries are inserted, the year blinks on the display BO. You can set the year by pressing the M button 5. To confirm and then set the month to\r\u003cbr\u003eto set, press the MODE button 6.\r\u003cbr\u003eNow you can set the month with the M button 5. Press the MODE button 6 to confirm and then set the day.\r\u003cbr\u003eFollow the instructions as described above to set the day, hours, and minutes.\r\u003cbr\u003eOnce you have set the minutes and press the START\/IO button 7, the date and time are set and the time will be displayed.\r\u003cbr\u003eIf no button is pressed for 20 seconds, the thermometer will automatically switch to the ready for use mode AT.\r\u003cbr\u003eEnd time setup: Press the START\/IO button 7 during time setup. The LCD screen will display the Date\/time symbol with \"--:--\". Then press the START\/IO button 7 to start the measurement. If you do nothing further, the thermometer will automatically\r\u003cbr\u003eturn off.\r\u003cbr\u003eChange current date and time: Hold the MODE button 6 for 8 seconds until the year starts blinking BO. You can now enter the new data as described above.\r\u003cbr\u003e\r\u003cbr\u003eBeeper setting\r\u003cbr\u003eHold the MODE button 6 for 3 seconds to set the beeper BP.\r\u003cbr\u003ePress the M button 5 to turn the beeper on or off. The beeper is activated when the sound symbol BP is displayed without a cross.\r\u003cbr\u003eWhen the beeper setting is selected, press the START\/IO button 7 for the \"ready for measurement\" mode; otherwise, the device will automatically be ready for measurement after 10 seconds. \r\u003cbr\u003e\r\u003cbr\u003eSwitching from body mode to object mode\r\u003cbr\u003ePress the START\/IO button 7. All symbols will appear on the screen 4 for 1 second.\r\u003cbr\u003eThe standard mode is the object mode AL. Press the MODE button 6 to switch from mode AM. To switch back to body mode, press the MODE button again.\r\u003cbr\u003e\r\u003cbr\u003eInstructions for use\r\u003cbr\u003eAlways remove the protective cap BS before use.\r\u003cbr\u003eMeasuring in body mode with automatic measurement and distance control\r\u003cbr\u003e1. Press the START\/IO button 7. All symbols will appear on the screen 4 for 1 second.\r\u003cbr\u003e2. A blinking «°C»\/«°F» symbol, a blue blinking trace light 2, and a beep signal indicate that the device is ready for a measurement AT.\r\u003cbr\u003e3. Remove hair, sweat, or dirt from the forehead to avoid inaccurate measurements.\r\u003cbr\u003e4. Aim the thermometer at the center of the forehead and maintain a distance of no more than 5 cm from the forehead.\r\u003cbr\u003e5. The device will automatically start when the measurement sensor 1 detects the required distance of less than 5 cm. The display will show a countdown (3, 2, 1); after 3 seconds, a long beep will indicate that the measurement is complete.\r\u003cbr\u003e6. Self-measurement: The self-measurement light 3 will help indicate when the measurement starts. Keep the thermometer aimed at the forehead until the light turns off.\r\u003cbr\u003e7. Read the measured temperature from the LCD display.\r\u003cbr\u003e8. For a subsequent measurement, keep the thermometer away from the forehead and wait until the «°C»\/«°F» symbol starts blinking again. Continue with the above steps 4 - 5.\r\u003cbr\u003e9. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\r\u003cbr\u003eMeasuring in object mode without automatic measurement 1. Press the START\/IO button 7. All symbols will appear on the screen 4 for 1 second.\r\u003cbr\u003e2. Press the MODE button 6 to switch to object mode.\r\u003cbr\u003e3. A blinking «°C»\/«°F» symbol, a blue blinking trace light 2, and a beep signal indicate that the device is ready for a measurement AT.\r\u003cbr\u003e4. Aim the thermometer at the center of the object you want to measure from a distance of no more than 5 cm. Now press the START\/IO button 7. After 3 seconds, a long beep will indicate that the measurement is complete.\r\u003cbr\u003e5. Read the measured temperature from the LCD display.\r\u003cbr\u003e6. For a subsequent measurement, wait until the «°C»\/«°F» symbol starts blinking again. Continue with the above steps 4 - 5.\r\u003cbr\u003e7. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\r\u003cbr\u003ePatients and thermometer must stay in a room with a constant temperature for at least 30 minutes.\r\u003cbr\u003eDo not measure during or immediately after feeding a baby.\r\u003cbr\u003eDo not use the thermometer in areas with excessively high humidity.\r\u003cbr\u003ePatients should not drink, eat, or exercise prior to\/during measurement.\r\u003cbr\u003eDo not remove the measuring device from the measuring area before you have heard the final beep.\r\u003cbr\u003e10 short beeps and a red illuminated LCD alert you that a temperature above 37.5 °C has been measured.\r\u003cbr\u003eAlways take the temperature at the same location, as temperature readings can vary from place to place.\r\u003cbr\u003edifferences.\r\u003cbr\u003eDoctors recommend measuring the temperature rectally for the first 6 months in newborns, as other measurement methods can often lead to unreliable results. If you still want to perform a non-contact measurement on newborns, please verify this with a rectal measurement.\r\u003cbr\u003eIn the following circumstances, it is recommended to take three measurements and take the highest result:\r\u003cbr\u003eChildren under three years old with a deficient immune system for whom having a fever is critical.\r\u003cbr\u003eIf the user is learning to use the thermometer for the first time, until he\/she is familiar with the device and obtains regular results.\r\u003cbr\u003eIf the measurement is unexpectedly low.\r\u003cbr\u003eTemperature measurements should not be compared with each other, as body temperature can\r\u003cbr\u003efluctuating due to time and ambient temperature, often the body temperature is highest in the evening and lowest in the morning hours.\r\u003cbr\u003e\r\u003cbr\u003eNormal body temperatures are:\r\u003cbr\u003eAxillary: 34.7 - 37.3 °C \/ 94.5 - 99.1 °F\r\u003cbr\u003eOral: 35.5 - 37.5 °C \/ 95.9 - 99.5 °F\r\u003cbr\u003eRectal: 36.6 - 38.0 °C \/ 97.9 - 100.4 °F\r\u003cbr\u003eMicrolife NC 200: 35.4 - 37.4 °C \/ 95.7 - 99.3 °F\r\u003cbr\u003e\r\u003cbr\u003eSwitchable from Celsius to Fahrenheit\r\u003cbr\u003eThis thermometer displays the temperature measurement in Fahrenheit and Celsius. To switch between °C and °F, press and hold the MODE button 6 for 3 seconds; the beeper symbol will be shown on the display. Press the MODE button again; the current measurement unit (\"°C\" or \"°F\" symbol) will be displayed in display AO. Switch between the measurement unit (°C\/°F) by pressing the M button 5. Once the measurement unit is selected, press the START\/IO button 7 to activate \"ready to measure\"; otherwise, the device will automatically turn off after 10 seconds AT.\r\u003cbr\u003e\r\u003cbr\u003e9. Calling up 30 measurements in memory mode \r\u003cbr\u003eThis thermometer displays the last 30 measurements, including date and time.\r\u003cbr\u003eCall mode AP: Press the M button 5 to enter call mode when the device is off. The memory symbol “M” is blinking.\r\u003cbr\u003eResult 1 – the last result AQ: Press the M button 5\r\u003cbr\u003eand release it to see the last result. Screen 1\r\u003cbr\u003eonly with memory symbol.\r\u003cbr\u003eBy pressing and releasing the M button 5 after the last 30 results have been called up, the above sequence will continue from result 1.\r\u003cbr\u003e\r\u003cbr\u003e10.Error messages\r\u003cbr\u003eMeasured temperature too high AR: The symbol “H” will\r\u003cbr\u003eappear when the temperature is higher than 43 °C \/ 109.4 °F in\r\u003cbr\u003ebody mode or 99.9 °C \/ 211.8 °F in object mode.\r\u003cbr\u003eMeasured temperature too low AS: The symbol “L” will\r\u003cbr\u003eappear when the temperature is lower than 34 °C \/ 93.2 °F in the\r\u003cbr\u003ebody mode or 0.1 °C \/ 32.2 °F in object mode.\r\u003cbr\u003e\r\u003cbr\u003eAmbient temperature too high BT: The symbol “AH” will appear when the ambient temperature is higher than\r\u003cbr\u003e40.0 °C \/ 104.0 °F.\r\u003cbr\u003eAmbient temperature too low BK: The symbol “AL” will appear when the ambient temperature is below 15.0\r\u003cbr\u003e°C \/ 59.0 °F in body mode or lower than 5.0 °C \/ 41.0 °F in object mode.\r\u003cbr\u003e\r\u003cbr\u003eError in operation BL:\r\u003cbr\u003e“The system is not working well.”\r\u003cbr\u003e“There 2”: The device is placed directly on the forehead or object. Maintain a distance of 1 - 5 cm. Never touch the underside (sensor area) of the measuring sensor.\r\u003cbr\u003eEmpty screen BM: Please check if the batteries are installed correctly. Also, check the polarity (\u003c+\u003e and \u003c-\u003e) of the batteries.\r\u003cbr\u003eEmpty battery status BN: If only the icon is displayed on the screen, you should replace the batteries immediately.\r\u003cbr\u003e\r\u003cbr\u003e11. Cleaning and Disinfecting\r\u003cbr\u003eUse a cotton swab or a cotton ball soaked in alcohol (70% isopropyl) to clean the thermometer housing and the probe tip. Ensure that no liquid enters the inside of the thermometer. Never use aggressive cleaning agents, thinners, or benzene for cleaning, and never submerge the thermometer in water or any other liquid. Make sure that no scratches occur on the surface of the probe lens and the display.\r\u003cbr\u003e\r\u003cbr\u003e12. Battery Replacement\r\u003cbr\u003eThis instrument comes with 2 long-life 1.5V AAA batteries, which should be replaced immediately when only the BN symbol is displayed.\r\u003cbr\u003eRemove the battery cover BQ by pushing in the direction shown.\r\u003cbr\u003eReplace the batteries – check the correct polarity as indicated by the symbols in the compartment.\r\u003cbr\u003eBatteries and electronic instruments must be disposed of according to local regulations, not with household waste.\r\u003cbr\u003e\r\u003cbr\u003eSee the leaflet for button mentions and location.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eComponents\u003c\/b\u003e\u003cbr\u003e-\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003eFollow the instructions for correct use. This documentation provides you with important operating and safety instructions regarding this device. Read the documentation carefully before using the device and keep it for future reference.\r\u003cbr\u003e\r\u003cbr\u003eThis device is intended for the purpose described in the user manual only. The manufacturer cannot be held liable for damage caused by improper use.\r\u003cbr\u003e\r\u003cbr\u003eNever immerse this device in water or other liquids. For cleaning, follow the instructions in the \"Cleaning and Disinfecting\" section.\r\u003cbr\u003e\r\u003cbr\u003eDo not use the device if you suspect it is damaged or if you notice anything unusual during use.\r\u003cbr\u003e\r\u003cbr\u003eNever open the device\r\u003cbr\u003e\r\u003cbr\u003eA normal biological process called vasoconstriction can occur in the early stages of fever, resulting in a lower skin surface temperature; the measured temperature with a thermometer may then be suspiciously low.\r\u003cbr\u003e\r\u003cbr\u003eIf the measurement result is not consistent with the patient's findings or is suspiciously low, repeat the measurement every 15 minutes or verify the result with another core body temperature measurement.\r\u003cbr\u003e\r\u003cbr\u003eThis device contains sensitive components and must be handled with care. Follow the storage and operating instructions as described in the \"Technical specifications\" chapter!\r\u003cbr\u003e\r\u003cbr\u003eAllow children to use the device only under adult supervision; small parts may be swallowed.\r\u003cbr\u003e\r\u003cbr\u003eDo not use the device close to strong electromagnetic fields such as mobile phones or radio installations. Maintain a distance of at least 3.3 meters from such devices when using this device.\r\u003cbr\u003e\r\u003cbr\u003eProtect it from:\r\u003cbr\u003e- extreme temperatures\r\u003cbr\u003e- shocks and drops\r\u003cbr\u003e- pollution and dust\r\u003cbr\u003e- direct sunlight\r\u003cbr\u003e- heat and cold\r\u003cbr\u003e- When the device will not be used for an extended period\r\u003cbr\u003emust be removed when the batteries are to be replaced\r\u003cbr\u003e\r\u003cbr\u003eWARNING: The measured results with this device do not constitute a diagnosis. It does not replace a consultation.\r\u003cbr\u003efrom a doctor, especially not when the symptoms do not match. Do not rely solely on the measurement result; always consider other symptoms as well as the feedback from the patient. In case of doubt, always contact your doctor.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdditional information\u003c\/b\u003e\u003cbr\u003eMedical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003eMicrolife AG Swiss Corporation, \nEspenstrasse 139, \n9443 Widnau, \nSwitzerland","brand":"Microlife","offers":[{"title":"1.00 Stuks","offer_id":58202575012185,"sku":"225702","price":55.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0888\/2343\/1513\/files\/4719003402914_A1N1.png?v=1780494849","url":"https:\/\/www.biolovers.nl\/en\/products\/microlife-non-contact-thermometer-nc200-1-stuks","provider":"Biolovers","version":"1.0","type":"link"}