{"product_id":"microlife-thermometer-pen-10-seconden-flextip-mt200-1-stuks","title":"Microlife Thermometer pen 10 seconds flextip MT200 1 Pieces","description":"\u003cb\u003eMicrolife Thermometer pen 10 seconds flextip MT200\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eMicrolife Thermometer pen 10 seconds flextip MT200\r\u003cbr\u003e\r\u003cbr\u003eHigh-Speed Digital thermometer\r\u003cbr\u003e• Highest accuracy in 10 seconds\r\u003cbr\u003e• Flexible tip\r\u003cbr\u003e• Hypoallergenic tip\u003cbr\u003eTechnical specifications\r\u003cbr\u003eType: Maximum thermometer\r\u003cbr\u003eMeasurement range: 32.0 °C to 42.9 °C\r\u003cbr\u003eTemp. \u003c 32.0 °C: display «L» for low (too low)\r\u003cbr\u003eTemp. \u003e 42.9 °C: display «H» for high (too high)\r\u003cbr\u003eMeasurement accuracy: ± 0.1 °C between 34 °C and 42 °C\r\u003cbr\u003e± 0.2 °C; 32.0 - 33.9 °C and 42.1 - 42.9 °C\r\u003cbr\u003eOperating conditions: 10 - 40 °C; 15-95 % maximum relative humidity\r\u003cbr\u003eStorage conditions: -25 - +60 °C; 15-95 % maximum relative humidity\r\u003cbr\u003eBattery: LR41 (1.5V) \/ SR41 (1.55V)\r\u003cbr\u003eBattery life: approximately 2700 measurements (with a new battery)\r\u003cbr\u003eIP Class: IP67\r\u003cbr\u003eReference to standards: EN 12470-3, clinical thermometers;\r\u003cbr\u003eASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC);\r\u003cbr\u003eIEC 60601-1-11\r\u003cbr\u003eExpected lifespan: 5 years or 10000 measurements\r\u003cbr\u003e- clinically tested\r\u003cbr\u003eThis device complies with the standards of the medical\r\u003cbr\u003edevices 93\/42\/EEC.\r\u003cbr\u003eTechnical changes reserved\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWhat this product is used for\u003c\/b\u003e\u003cbr\u003eMeasuring body temperature\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003eTurning on the thermometer\r\u003cbr\u003eTo turn on the thermometer, press the ON\/OFF button 1; a\r\u003cbr\u003ea short beep indicates that the thermometer is turned on. A display test\r\u003cbr\u003eis being performed. All functionality will be displayed.\r\u003cbr\u003eThe last measurement will automatically be shown on the display 2\r\u003cbr\u003efor 2 seconds with the «M» symbol.\r\u003cbr\u003eAt a room temperature of less than 32 °C, the first\r\u003cbr\u003esymbol «L» in the display, then the symbol «°C» blinks in\r\u003cbr\u003ethe display 2. The thermometer is now ready for use.\r\u003cbr\u003eFunction test\r\u003cbr\u003eThe operation of the thermometer is automatically tested each time\r\u003cbr\u003ewhen it is turned on. If a defect is detected\r\u003cbr\u003e(measurement inaccurate), this is indicated by «ERR» in the\r\u003cbr\u003edisplay, and measuring is no longer possible. In this case, the thermometer\r\u003cbr\u003ewill be replaced.\r\u003cbr\u003e\r\u003cbr\u003eUse of the thermometer\r\u003cbr\u003eChoose the desired measurement method. During measurement, the current\r\u003cbr\u003etemperature is continuously displayed and the «°C» symbol is blinking.\r\u003cbr\u003eIf there are 10 beeps and the «°C» no longer blinks, then the\r\u003cbr\u003etemperature measured and can be read.\r\u003cbr\u003eWhen the temperature is higher than 37.5 °C, 10 beeps will sound.\r\u003cbr\u003eto alert the patient that he\/she may have a fever.\r\u003cbr\u003ehave. Reference: Oral measured temperature.\r\u003cbr\u003eTo compare measurement results, you must wait at least 1 minute\r\u003cbr\u003emeasure intervals.\r\u003cbr\u003eTo extend the battery life, you can\r\u003cbr\u003eturn off by briefly pressing the ON\/OFF button 1. Otherwise, the\r\u003cbr\u003ethermometer will automatically turn off after about 10 minutes.\r\u003cbr\u003e\r\u003cbr\u003eMeasurement methods \/ Normal body temperature\r\u003cbr\u003e Under the armpit (axillary) \/ 34.7 - 37.3 °C\r\u003cbr\u003ePat the armpits dry with a clean towel. Place the measuring sensor\r\u003cbr\u003e4 under the arm in the middle of the armpit, so that the tip touches the skin\r\u003cbr\u003etouching and place the arm next to the body. This ensures that the\r\u003cbr\u003eroom temperature does not affect the measurement, as the armpit is more\r\u003cbr\u003eneeds time to reach a temperature. Wait 5 minutes,\r\u003cbr\u003eregardless of the beep sound.\r\u003cbr\u003e In the mouth (oral) \/ 35.5 - 37.5 °C\r\u003cbr\u003eDo not eat or drink anything hot or cold 10 minutes before the measurement. The mouth\r\u003cbr\u003emust remain closed for 2 minutes before you start the measurement.\r\u003cbr\u003ePlace the thermometer under the tongue, to the left or right of the frenulum.\r\u003cbr\u003eThe tip of the thermometer must have good contact with\r\u003cbr\u003ethe tissue. Close the mouth and breathe evenly through the nose to\r\u003cbr\u003eto prevent the measurement from being affected by breathing through\r\u003cbr\u003ethe mouth.\r\u003cbr\u003eIf this is not possible due to blocked airways, it must\r\u003cbr\u003eanother measuring method should be used.\r\u003cbr\u003eMeasurement time approx.: 10 seconds!\r\u003cbr\u003e In the anus (rectal) \/ 36.6 - 38.0 °C\r\u003cbr\u003eGently insert the thermometer's measuring sensor 2 to 3 cm\r\u003cbr\u003ein the anal opening.\r\u003cbr\u003eThe use of a protective cap and the use of petroleum jelly is\r\u003cbr\u003erecommended.\r\u003cbr\u003eIf you are unsure about this measurement method, you should consult a professional\r\u003cbr\u003eto consult for guidance\/training.\r\u003cbr\u003eMeasurement time approx.: 10 seconds!\r\u003cbr\u003e\r\u003cbr\u003eCleaning and disinfecting\r\u003cbr\u003eFor disinfection in a home environment, use a cotton swab of\r\u003cbr\u003e70% isopropyl alcohol or a cotton pad that is moistened with\r\u003cbr\u003e70% isopropyl alcohol to remove dirt from the thermometer probe.\r\u003cbr\u003ewiping (note: consider the application and safety instructions of\r\u003cbr\u003ethe manufacturer of the disinfectant). Always start by wiping\r\u003cbr\u003efrom the end of the thermometer probe (approximately in the middle\r\u003cbr\u003eof the thermometer) towards the thermometer tip. Then the\r\u003cbr\u003eentire thermometer probe (see number 5 in the drawing) to be\r\u003cbr\u003eimmersed in 70% isopropyl alcohol for at least 70% 5\r\u003cbr\u003eminutes (max. 24 hours). Allow the disinfectant after immersion\r\u003cbr\u003edry for 1 minute before the next use. Immerse or wipe the\r\u003cbr\u003edo not cover the screen to prevent fading.\r\u003cbr\u003eThe thermometer is not intended for professional use.\r\u003cbr\u003e\r\u003cbr\u003eWhen the symbol «» appears on the display, the battery\r\u003cbr\u003eis empty and needs to be replaced. To replace the battery\r\u003cbr\u003ethe cover of the battery compartment must be removed 3. Place\r\u003cbr\u003ea new battery with the + on the top. Make sure you have a\r\u003cbr\u003ehas a battery of the same type on hand. Batteries can be found in almost\r\u003cbr\u003epurchased at all electronics stores.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eComponents\u003c\/b\u003e\u003cbr\u003eThermometer\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003eFollow the instructions for correct use. This documentation provides you with important operating and safety instructions regarding this device. Read the documentation carefully before using the device and keep it for future reference.\r\u003cbr\u003e- This device may only be used for measuring human body temperature via oral, rectal, or axillary.\r\u003cbr\u003eDo not attempt to take temperatures in other places, such as in the ear, as this may lead to inaccurate measurements and injury.\r\u003cbr\u003e- Do not use this device if you suspect it is damaged or if you have noticed anything unusual.\r\u003cbr\u003e- We recommend cleaning this device according to the cleaning instructions before first use for personal hygiene.\r\u003cbr\u003e- The measurement time until the sound signal must, without exception, be at least maintained!\r\u003cbr\u003e- Please note that for different measurement locations, even after the beep, multiple measurements may be necessary.\r\u003cbr\u003e- Do not attempt rectal measurements on individuals with rectal conditions. This may worsen the condition.\r\u003cbr\u003e- Allow children to use the device only under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the device is equipped with cables or hoses.\r\u003cbr\u003e- Do not use the device close to strong electromagnetic fields such as mobile phones or radio installations. Maintain a distance of at least 3.3 meters from such devices when using this device.\r\u003cbr\u003e- Protect the instrument from shocks and falls!\r\u003cbr\u003e- Do not bend the thermometer probe more than 45 °!\r\u003cbr\u003e- Avoid ambient temperatures above 60 °C. NEVER boil the instrument!\r\u003cbr\u003e- Only use the disinfectants mentioned in the Cleaning and Disinfecting section to clean the device to prevent damage to the device.\r\u003cbr\u003e- We recommend having this device tested for accuracy every two years or after a mechanical impact (e.g., falling). Please contact your local Microlife dealer for this.\r\u003cbr\u003e\r\u003cbr\u003eWARNING: The measured temperature with this device is not a diagnosis! Therefore, do not rely solely on the measured result.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eStorage advice\u003c\/b\u003e\u003cbr\u003eBatteries and electronic instruments must be disposed of according to local regulations, not with household waste.\r\u003cbr\u003e\r\u003cbr\u003eStore at a temperature between -25°C and 60°C\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdditional information\u003c\/b\u003e\u003cbr\u003eWarranty\r\u003cbr\u003eThis device has a lifetime warranty from the date of purchase.\r\u003cbr\u003eDuring this warranty period, Microlife will repair the defective product free of charge.\r\u003cbr\u003erepair or replacement.\r\u003cbr\u003eOpening or making changes to the device voids the warranty\r\u003cbr\u003einvalid.\r\u003cbr\u003eThe following items are excluded from warranty:\r\u003cbr\u003e- Transport costs and transport risks.\r\u003cbr\u003e- Damage caused by improper use or non-compliance with the\r\u003cbr\u003einstructions for use.\r\u003cbr\u003e- Damage caused by leaking batteries.\r\u003cbr\u003e- Damage caused by falling or improper use.\r\u003cbr\u003e- Packaging \/ storage material and instructions for use.\r\u003cbr\u003e- Regular checks and maintenance (calibration).\r\u003cbr\u003e- Accessories and consumables: Battery.\r\u003cbr\u003eIf warranty is needed, please contact the dealer where you purchased the\r\u003cbr\u003eproduct you purchased, or with your local Microlife service. \r\u003cbr\u003e\r\u003cbr\u003eYou can via\r\u003cbr\u003econtact our website with your local Microlife dealer:\r\u003cbr\u003ewww.microlife.com\/support\r\u003cbr\u003eThe compensation is limited to the value of the product. The warranty\r\u003cbr\u003eis granted if the complete product is returned with the\r\u003cbr\u003eoriginal invoice. Repair or replacement under warranty extends\r\u003cbr\u003eor extends the warranty period. Legal claims and rights\r\u003cbr\u003eof consumers are not limited by this warranty.\u003cbr\u003eMedical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003eMicrolife Corporation, \n9F, 431 RuiGuang Road , \nNeiHu Taipei, \n11492 Taiwan, \nChina","brand":"Microlife","offers":[{"title":"1.00 Stuks","offer_id":57994163192153,"sku":"788909","price":11.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0888\/2343\/1513\/files\/4719003070021_A1N1_9d26965a-f800-487f-88f0-70ee6d29d72f.png?v=1781796877","url":"https:\/\/www.biolovers.nl\/en\/products\/microlife-thermometer-pen-10-seconds-flextip-mt200-1-pieces","provider":"Biolovers","version":"1.0","type":"link"}